Enter the power load in watts (W)
Enter the supply voltage in volts (V)
Between 0 and 1. Typical: 0.8–1.0
Calculated Current
-- A
-- kW
Apparent Power:-- VA
Apparent Power (kVA):-- kVA
Horsepower:-- HP
Reactive Power:-- VAR
Applied Formula:I = P ÷ (V × PF)

⚡ Instant conversion using P = V × I × PF. Power factor is applied explicitly so nothing is assumed silently.

Watts to Amps Formulas

DC Circuit Formula

I(A) = P(W) ÷ V(V)

For direct current circuits such as batteries, solar panels and 12V automotive systems.

AC Single-Phase Formula

I(A) = P(W) ÷ (V(V) × PF)

For standard residential wall outlets and single-phase household equipment.

AC Three-Phase (Line-to-Line)

I(A) = P(W) ÷ (√3 × V_LL(V) × PF)

For industrial three-phase supplies measured between two phases (e.g. 208V, 400V, 480V).

AC Three-Phase (Line-to-Neutral)

I(A) = P(W) ÷ (3 × V_LN(V) × PF)

For three-phase supplies measured from a single phase to neutral (e.g. 120V, 230V).

How to Convert Watts to Amps

Watts measure how fast energy is used; amps measure how much current flows to deliver it. Because watts = volts × amps, dividing the wattage by the supply voltage gives the current the equipment will draw.

  • Step 1 — Identify the circuit. DC, single-phase AC and three-phase AC all use different multipliers. A DC 12V system and a 12V AC system behave differently in practice.
  • Step 2 — Find the real power. Use the nameplate wattage of the load, or the sum of every load on the circuit. For motors, use the rated output plus any no-load overhead.
  • Step 3 — Use the actual supply voltage. Nominal ratings drift — a 120V circuit measured under load is often closer to 118–122V, which changes the result slightly.
  • Step 4 — Apply the power factor. Inductive loads (motors, compressors, fluorescent ballasts, older switch-mode supplies) draw more current than their wattage alone suggests. Divide by a PF of 0.8–0.95 to get the true draw.

A useful sanity check: doubling the supply voltage halves the current for the same wattage. A 2,400W heater on 240V pulls 10A, but the same heater on 120V pulls 20A — which is why high-power appliances are almost always 240V.

Watts to Amps Reference Table (at PF = 1.0)

Values calculated at Power Factor (PF) = 1.0. For inductive loads (motors, AC units) the real current will be higher.

Power (Watts)12V DC120V AC (1-Phase)230V AC (1-Phase)240V AC (1-Phase)400V AC (3-Phase L-L)
100 W8.33 A0.83 A0.43 A0.42 A0.14 A
250 W20.83 A2.08 A1.09 A1.04 A0.36 A
500 W41.67 A4.17 A2.17 A2.08 A0.72 A
750 W62.50 A6.25 A3.26 A3.13 A1.08 A
1,000 W83.33 A8.33 A4.35 A4.17 A1.44 A
1,500 W125.00 A12.50 A6.52 A6.25 A2.17 A
2,000 W166.67 A16.67 A8.70 A8.33 A2.89 A
3,000 W250.00 A25.00 A13.04 A12.50 A4.33 A
5,000 W416.67 A41.67 A21.74 A20.83 A7.22 A

How Many Amps is...? (Common Power Ratings)

How many amps is 100 watts?

At 120V AC, 100 watts draws 0.83 amps. At 12V DC it draws 8.33 amps.

How many amps is 500 watts?

At 120V AC, 500 watts draws 4.17 amps. At 230V AC it draws 2.17 amps.

How many amps is 1000 watts?

At 120V AC, 1,000 watts draws 8.33 amps. At 240V AC it draws 4.17 amps.

How many amps is 1500 watts?

At 120V AC, 1,500 watts draws 12.5 amps — close to the 13A limit of a standard UK socket.

How many amps is 2000 watts?

At 120V AC, 2,000 watts draws 16.67 amps. At 230V AC it draws 8.70 amps.

How many amps is 3000 watts?

At 240V AC, 3,000 watts draws 12.5 amps. At 120V AC it needs 25 amps.

Frequently Asked Questions

How do you convert watts to amps?

Divide the power in watts by the voltage in volts. For DC circuits, I = P ÷ V. For single-phase AC, divide by voltage multiplied by the power factor: I = P ÷ (V × PF). For three-phase AC, divide by √3 × V × PF for line-to-line voltage, or 3 × V × PF for line-to-neutral voltage.

How many amps is 100 watts?

At 120V AC with a power factor of 1.0, 100 watts draws 0.83 amps (100 ÷ 120 = 0.83). At 12V DC the same 100 watts draws 8.33 amps.

How many amps is 1500 watts?

At 120V AC with a power factor of 1.0, 1,500 watts draws 12.5 amps. At 230V AC it draws 6.52 amps.

How many amps does a 12V device draw?

Divide the wattage by 12. A 60W 12V device draws 5 amps, a 120W device draws 10 amps, and a 300W device draws 25 amps.

Do I need the power factor to convert watts to amps?

Yes for AC circuits. Real power (watts) equals apparent power (VA) multiplied by the power factor. If you ignore it, you will underestimate the current a load draws — an inductive motor at PF 0.8 draws 25% more current than the same wattage at PF 1.0.

How do I convert watts to amps for a three-phase system?

For line-to-line voltage (e.g. 400V), divide watts by √3 × V × PF. For line-to-neutral voltage (e.g. 230V), divide watts by 3 × V × PF. Both give the same answer for the same system.

Why is the current different at 120V and 240V?

Power is the product of voltage and current, so at twice the voltage the same wattage needs half the current. That is why 240V appliances draw roughly half the amps of their 120V equivalents — and why they need thicker cables only over shorter runs.

Can I use this calculator to size a circuit breaker?

This tool calculates the theoretical current draw of a load. Circuit breaker sizing also depends on whether the load is continuous (NEC requires continuous loads to stay under 80% of the breaker rating), ambient temperature, conductor size and local code. Always consult a licensed electrician.

⚠️ Safety & Electrical Disclaimer

This calculator provides theoretical current calculations based on Ohm's law and standard AC power equations (P = V × I × PF). It does NOT determine circuit breaker requirements, conductor wire gauge sizes, or compliance with local electrical codes (such as NEC or IEC). The NEC generally requires that continuous loads not exceed 80% of a circuit breaker's rated capacity, though specific requirements depend on equipment ratings, ambient conditions, and the applicable code edition. Always consult a licensed electrician and your local authority having jurisdiction (AHJ) for physical wiring projects.

Related Electrical Calculators

Related Electrical Tools & Testing Gear

These recommendations are informational only. We do not currently use affiliate links or earn commissions from them.

Digital Clamp Meters

Measure the real current of any circuit and confirm what this calculator predicts.

Top Essential

Plug-in Power Monitors

Track real-time watts, kWh and power factor for household appliances.

Popular

Portable Power Stations

Size an off-grid battery system from the amps and watts your equipment needs.

Off-Grid